Output Frequency: | 50/60Hz |
---|---|
Output Voltage: | 220-240V |
Output Power: | >1000W |
Application: | Electric Tools |
Item Name: | 10000W DC to AC Power Inverter |
Size: | 680mm*350mm*280mm |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Products Advantages
Products Parameters
Model | 10-40KW | |
Rate Power | 10-40KW | |
Instant power | Three times | |
DC Input | DC voltage | 96V(10K);192V(10-20K);240V(30-40K) |
Battery No. | 12V battery: 8pcs/16pcs/20pcs | |
Battery type | Maintenance-free lead-acid batteries | |
AC Input | Phase | Single Phase |
Frequency | 50Hz ± 10% | |
AC input | 110V(85-140V)/220V(165-275V) (L+N+G) | |
AC AVR output | 110/220VAC (L+N+G)±10% | |
Charging | Floating charge voltage | DC96V:116V/DC192V:232V/DC240V:280V |
Overcharge protect voltage | DC96V:124V/DC192V:248V/240V:310V | |
Charge current | 10-20A adjustable ( Charging current can be customized ) | |
Invert output | Output voltage | 110V/220VAC (L+N+G)±1% |
Frequency | 50Hz ± 0.1% | |
THD | ≤ 3% (Linear load) | |
Dynamic response | 5% (0%~100% load) | |
Crest factor | 3:1 | |
Invert efficiency | 97% | |
Alarm | Buzzing and LCD screen flicker | |
Protection function | Ac overvoltage, under voltage, DC overvoltage, under voltage, Overload, Output short circuit | |
Overload capacity | >100-120% alarm 60s then shutdown; >100-120%, back to normal working when cut down loads during alarm 60s; >150% Instant shutdown |
|
Communication interface | USB/RS232/SNMP(option) | |
Protection class | IP21 | |
Surge handling capability | 10/700US,5KVA;8/20US,20KA | |
Noise dB | ≤45db | |
Cooling mode | Forced ventilation | |
Ambient Temperature | Temperature 0-40ºC, relative humidity 10%-90%, elevation<1000m |
Rated voltage | 96V |
Rated current | 100A |
Maximum protection current | 104A |
Battery voltage identification range | DC72-120V |
MPPT Operating voltage range | DC130-DC180V |
PV input low voltage protection point | DC120V |
PV input low pressure recovery point | DC130V |
Maximum PV input power | 13600W |
Limit input voltage | DC225V |
PV input overvoltage protection point | DC230V |
PV input overvoltage recovery point | DC225V |
charging method | 3 stage constant current(MPPT),equalizing charge, float charge |
System type | 96V Automatic identify (72V manual setting) |
Static power consumption | 4W |
Machine efficiency | 96.5% |
PV module utilization | 99.97% |
Float voltage (can be customized) | DC110V |
Average charge voltage(can be customized) | DC113.6V |
Recommended PV module voltage | 144V-180V |
Temperature compensation | -3mV°C/2V |
Temperature protection | +85°C |
Temperature rise protection | 85°C or more to reduce power output |
Protective function | PV array short circuit overvoltage, overcurrent reverse polarity protection, |
battery overcharge, reverse protection, Under voltage protection | |
Working temperature | -10°C~+45°C |
Humidity | 0~90%RH (Not condensation) |
Altitude | 0~3000m |
Security Level | CE, PSE, FCC, EMC |
Mechanical protection class | IP21 |
Optional battery type | Lead-acid battery, colloidal batteries, liquid batteries, lithium batteries (Also can be customized for other types of battery charging) |
Protect function | Status | Protective action | Recovery |
AC input overvoltage or undervoltage | Voltage above or below the setting value | Switch to invert output automatically | After troubleshooting, inverter will automatically return to normal working condition. |
DC input overvoltage or undervoltage | Voltage above or below the setting value | Stop output | |
Over-temperature | Internal working temperature is too high | AC input state: buzzing; DC input state: buzzing and stop output | Rule out the reasons leading to high temperature, inverter will work normal. |
Output overload | load power is bigger than the rated power | AC input mode: alarm and screen flicker; DC input mode: alarm and stop output |
After troubleshooting, need to restart the inverter to back to normal working condition. |
Payment Terms | T/T | EXW | 30% T/T in advance, paid the balance before shipment |
FOB | |||
CFR(C&F) | 30% T/T in advance, paid the balance against copy of B/L | ||
CIF | |||
L/C | L/C amount above 50,000 usd, we can accept L/C at sight | ||
West Union | Amount lower than 5000usd | ||
Paypal | |||
Delivery time | 10 working days after receiving payment for one container |
Suppliers with verified business licenses