Inverter Efficiency: | 99.5 |
---|---|
Output Type: | AC |
Output Frequency: | 50/60Hz |
Output Current: | 300A |
Output Voltage: | 220-240V |
Input Voltage: | 384V |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
1. The main circuit use DSP chip which produced by American Tl Company, Japan Mitsubishi IGBT module, drive protection is Japan's Mitsubishi chip, off grid output use isolation transformer, safe and reliable .
Products Parameters
Model | 10220 | 15220 | 20220 | 30380 | 40380 | 50380 | 60380 | 80380 | 100380 | |
DC input | Input rating voltage ( VDC ) | 220 | 380 | |||||||
Input rating current ( A) | 50.5 | 75.7 | 101 | 85.8 | 114.4 | 143 | 171.6 | 228.8 | 286 | |
Input DC voltage allowing range ( VDC ) | 187-300 | 335Vdc-650Vdc | ||||||||
AC output | Output rating power ( kW ) | 10KW | 15KW | 20KW | 30KW | 40KW | 50KW | 60KW | 80KW | 100KW |
Output rating voltage and frequency | 380 Vac, 50Hz | |||||||||
Output rating current ( A) | 15.2 | 22.7 | 30.3 | 45.5 | 60.6 | 75.9 | 91.1 | 121.5 | 151.9 | |
Output voltage precision (V ) | AC380/220V±3% | |||||||||
Output frequency precision ( Hz) | 50±0.05 | |||||||||
Wave distortion ( THD ) (liner load ) | <3% | |||||||||
Dynamic response (load 0 100% ) | 5% | |||||||||
Power factor ( PF ) | 0.8 | |||||||||
Overload ability | 150%,10 seconds | |||||||||
Crest factor ( CF ) | 03:01 | |||||||||
Inverted efficiency (80%resistance load) | 90% | 92% | ||||||||
Insulation strength (input and output) | 1500 VAC.lminute | |||||||||
Noise (lmeter) | <50dB | |||||||||
Using condition temperature | -25°C~ + 55°C | |||||||||
Humidity | 0-95% , no condensing | |||||||||
Altitude ( m ) | <5000(0ver 1000 meters to reduce the using amount as GB/T3859.2) | |||||||||
Dimension (width, depth, height) mm | 580*510*1250 | 650*580*1500 | 520*1160*1370 | 600*1320*1490 | ||||||
Protection function | Input reversing protection, input low-voltage protection, output over-load protection, output short-circuit protection, over-heat protection |
Tenical/Model TYC- | 100A96 | 50A220 | 100A220 | 150A220 | 50A380 | 100A380 | 150A380 | |
Controller electric specification | Rated Voltage(V) | 96 | 220 | 380 | ||||
Rated Charge Current(A) | 100 | 50 | 100 | 150 | 50 | 100 | 150 | |
Battery max input voltage(V) | 120 | 300 | 500 | |||||
Max PV input voltage(V) | 200 | 550 | 750 | |||||
Max PV input power(W) | 10000 | 11000 | 22000 | 33000 | 19000 | 38000 | 57000 | |
PV array input control way | 1 | 1 | ||||||
Charge method | MPPT | |||||||
Battery Equlization charge voltage(Vdc) | 115 | 247( cab be set) | 430( cab be set) | |||||
Self-consumption(mA) | <300 | |||||||
Communication | RS485 | |||||||
Rated Efficiency | ≥95% | |||||||
Protection level | IP20 | |||||||
Operating environment | Operating temperature | -20ºC~+50ºC | ||||||
Relative humidity | <90% No condensation | |||||||
Altitude | 2000m | |||||||
Dielectric strength(Input & Output) | 1500VAC,1 mintues | |||||||
Sound (1 meter) | ≤50dB | |||||||
Protection function | Input reverse protection, Input discharge protection ,Input over voltage protection ,Output Overload protection ,Input short-circuit protection, Over-heat protection | |||||||
Chassis dimensions(width * lenth * height) | 482*420*222 | 540*500*910 | 482*420*222 | 540*500*910 |
Protect function | Status | Protective action | Recovery |
AC input overvoltage or undervoltage | Voltage above or below the setting value | Switch to invert output automatically | After troubleshooting, inverter will automatically return to normal working condition. |
DC input overvoltage or undervoltage | Voltage above or below the setting value | Stop output | |
Over-temperature | Internal working temperature is too high | AC input state: buzzing; DC input state: buzzing and stop output | Rule out the reasons leading to high temperature, inverter will work normal. |
Output overload | load power is bigger than the rated power | AC input mode: alarm and screen flicker; DC input mode: alarm and stop output |
After troubleshooting, need to restart the inverter to back to normal working condition. |
Payment Terms | T/T | EXW | 30% T/T in advance, paid the balance before shipment |
FOB | |||
CFR(C&F) | 30% T/T in advance, paid the balance against a copy of B/L | ||
CIF | |||
L/C | L/C amount above 50,000 USD, we can accept L/C at sight | ||
West Union | Amount lower than 5000usd | ||
Paypal | |||
Delivery time | 10 working days after receiving payment for one container |